VOC on-line monitoring system of fixed pollution source(GC8000)


Introduction:


VOCs is a general term of a series of volatile organic compounds, which is an important air pollutant. When it exists in the air, it will produce chemical reactions to produce secondary aerosols (SOA) and other fine particles, as well as the chemical pollution caused by ozone. Sy-voc900 and sy-gc8000 VOC on-line monitoring systems are designed and developed according to the function, structure, performance, installation and test required in HJ 38-2017 standard of national determination of total hydrocarbon, methane and non methane total hydrocarbon in waste gas from fixed pollution sources! It can measure non methane hydrocarbon, benzene series, alcohol, ketone, aldehyde, etc Sy-gc8000 explosion-proof VOC online monitoring system System composition: explosion-proof high temperature sampling probe, explosion-proof sampling pipeline, high temperature pretreatment system, original Yokogawa explosion-proof FID online chromatograph and data acquisition system. Technical parameters:
detectorHydrogen   flame FIDCombustion   gasH2   99.999% (about 2.4bar)
Detection   range0-1pm   to 0-100%Combustion   gas flow60-300ml/min
Minimum   detection limit5ppbCombustion   gas interface1/4” Pipe connection
Volume   renaturation士1%carrier   gasN2   99.999% (about 2.0bar)
Range   analysis period          2min   (about 5min for Benzene Series)Carrier   gas interface1/4” Pipe connection
Analog   outputAs   needed (up to 32 points)Carrier   gas flow rate60-300ml/min
Digital   outputone   o'clockambient   temperature10-50℃
Calibration:Automatic   to manualhumidity0-95%(No   condensation)
Size:W580×D430×H935mmPower   Supply:220VAC士10%,50Hz士5%
display12.1   "full touch screenPower:1.3KW
Installation:Wall   mounted installationWeight:About   100kg
Sample   connection:1/8   pipe connectionElectrical   output:1   (fault plan, optional 20 point vie
Sample   gas flow:6L   / h (pressure 0.5 ~ 4bar)Instrument   wind4-6bar   (less than 0.1ppm) a
Analog   output:8-way   4-20mA isolationInstrument   air assisted gas interface1/4” Pipe connection
Digital   output:RS422,   RJ45 EthernetInstrument   air assisted gas flowAbout   20L/H(0.35~9bar)
Digital   input:32   touch digital scaleInstrument   air scavenging interface1/4”NPT  Internal thread
Smoke   control levelFMS   1 DV groupInstrument   air volumeAbout   140L / h (0.35 ~ 9BAR)
 VOC system product features: ■ the specific VOC gas composition is relatively complex, and each enterprise's working conditions are different. Only by designing suitable systems according to different working conditions can the accurate and stable operation be achieved! ■ the professional technical team who has been engaged in the instrument industry for 15 years will provide you with perfect application solutions for various industries! Point to point professional services! ■ for more than ten years, we only do gas online monitoring system, and provide perfect solutions for different industries and processes! Keep improving is our only criterion! According to the impurities in the process, a three-stage filtration system is designed and equipped with a heated back blow filter probe to ensure that the gas analyzer can work stably and measure accurately; the internationally advanced internal and external pulse vibration back blow technology is adopted, and the unique quick disassembly design makes the maintenance convenient and the maintenance workload small. Patent No. of sampling probe: ZL 2013 2 0634010.1 ● add PID sensor for reference correction and compensation of data! ● the system is equipped with many sensors such as humidity sensor, velocity sensor and pressure sensor to monitor the operation in real time, so as to ensure the stability of the equipment and the work of colleges and universities. ● the whole system is equipped with remote calibration and diagnosis functions as standard, which can realize on-site calibration, maintenance and improve system performance in the company! ● add mobile app function, and customers can view field data through mobile phone at any time! ● sampling American ADI thermostatic pump and imported pipe valves ● the data acquisition system is highly integrated in the cabinet, the operation interface is more reasonable and user-friendly, and the cycle adjustment such as sampling and back blowing is increased. ● it has data comparison, processing, automatic calibration, range setting, over limit alarm interlocking functions. The system adopts PLC control and intelligent analysis instrument, with high degree of automation, small maintenance workload and fast and convenient data processing  VOC online monitoring software

clip_image003.png

Software patent No:2016SR157036

371--------m.wyc-cn.cn

317--------m.nhjzy.cn

362--------m.pncesfk.cn

222--------m.gldf.com.cn

595--------m.zgcol.com.cn

449--------m.abc-01.cn

297--------m.hooming.cn

105--------m.canadanice.com.cn

269--------m.xrwi.cn

144--------m.cdlhts.cn